Coal-fired power plant ash removal case
Unit: 300MW
Number of dust collection bags: 9720
Number of dust removal rooms: 5 rooms
Dust bag material: PTFE/P84 ultra-fine impregnated filter bag
Use time of cloth bag: 2 years
Blowing method: rotary back blowing
Operating temperature: 130℃
Dust collector problem: the bag has high running resistance, frequent dust removal, and can not run under high load
Service content: bag cleaning/fluorescent powder leakage
Working time: 8h*6days (4 devices)
Resistance before cleaning: 70% load about 2400pa
Resistance after dust removal: about 1200pa at full load
On-site test bag resistance drop: 62.19%